Thermal underfloor heating
Underfloor heating mixing group
This mixing valve makes the use of the open modular distributor the right choice for high temperature heating systems. The valve mixes the hot water from the boiler with the return water and offers the underfloor heating system, the optimum operating temperature. The mixing valve is provided with a Grundfos ALPHA 2l Class A electronic pump,..
90° Bend support tube size ø 14-17mm 2 pcs
90° bend support maintains the heating pipes in an angle of 90° and allows you to easily and quickly process the tubes. This support is very suitable for supporting tubes in corners when installing in ceilings, floors or support from the manifold of the underfloor heating system...
90° Bend support tube size ø 18-20mm 2 pcs
90° bend support maintains the heating pipes in an angle of 90° and allows you to easily and quickly process the tubes. This support is very suitable for supporting tubes in corners when installing in ceilings, floors or support from the manifold of the underfloor heating system..
Aluminium reflection foil 20 m. x 1,5 m. ( 30 m² )
Aluminium reflection foil consists a plastic webbing and an aluminum top layer. The foil reflects heat to the screed and displaces cold through the sub-floor, so it is an extremely effective heat conductor. The foil is designed for direct application under floor heating pipes and can be easily cut to size...
Aluminium reflection foil Rol 50m x 1,5m (75m²)
Aluminium reflection foil consists a plastic webbing and an aluminum top layer. The foil reflects heat to the screed and displaces cold through the sub-floor, so it is an extremely effective heat conductor. The foil is designed for direct application under floor heating pipes and can be easily cut to size..
Castellated Plates 28mm (11mm EPS: 10 pcs / 10m²)
Castellated plates are specifically designed to simplify the preparation of the floor for the installation of heating pipes, which reduces the installation time. In addition the studded plates make it possible to confirm underfloor heating pipes in a quick and easy way. Available as non-insulated and isolated in 28 or 47mm...
Castellated Plates 28mm (11mm EPS: 20 pcs / 20m²)
Castellated plates are specifically designed to simplify the preparation of the floor for the installation of heating pipes, which reduces the installation time. In addition the studded plates make it possible to confirm underfloor heating pipes in a quick and easy way. Available as non-insulated and isolated in 28 or 47mm...
Castellated Plates 47mm (30mm EPS: 10 pcs / 10m²)
Castellated plates are specifically designed to simplify the preparation of the floor for the installation of heating pipes, which reduces the installation time. In addition the studded plates make it possible to confirm underfloor heating pipes in a quick and easy way. Available as non-insulated and isolated in 28 or 47mm..
Castellated Plates uninsulated 17mm (10 pcs / 10m²)
Castellated plates are specifically designed to simplify the preparation of the floor for the installation of heating pipes, which reduces the installation time. In addition the studded plates make it possible to confirm underfloor heating pipes in a quick and easy way. Available as non-insulated and isolated in 28 or 47mm...
Castellated Plates uninsulated 17mm (30 pcs / 30m²)
Castellated plates are specifically designed to simplify the preparation of the floor for the installation of heating pipes, which reduces the installation time. In addition the studded plates make it possible to confirm underfloor heating pipes in a quick and easy way. Available as non-insulated and isolated in 28 or 47mm..
Eco Pump Switch
This automatic pump switch will turn on the circulation pump of the heating if the temperature of the heating water is higher than the temperature setting and turn off when it is below the programmed temperature. This ensures that the pump is not switched on 24 hours a day and this can save significantly on energy costs...
Expansion profile - Profileset with adhesive tape 5 pcs 2m (10m/l)
In areas which are larger than 40m. it is often necessary to take advantage of expansion profile in the floor. Dilatatieprofielen will prevent the covering floor from bursting in larger rooms through expanding and shrinking...
MAGNUM Tube PE-RT 16 x 2 / 120 m
Density0,933 g/cm3 (ASTM D-792)Linear expansion coefficient, 20⁰C - 70⁰C0,19 mm/mK (DIN 53752 A)Thermal conductivity at 60⁰C0,4 Watt/mK (DIN 52612-1)Softening Point (Vicat) 122⁰C (ASTM D-1525)Maximum elongation at break > 800% (ISO 527-2)Bending radius 5 x DiametreOxygen DensityEVOH Layer (DIN 4726)MAGNUM Tube underflo..
MAGNUM Tube PE-RT 16 x 2 / 240 m
Density0,933 g/cm3 (ASTM D-792)Linear expansion coefficient, 20⁰C - 70⁰C0,19 mm/mK (DIN 53752 A)Thermal conductivity at 60⁰C0,4 Watt/mK (DIN 52612-1)Softening Point (Vicat) 122⁰C (ASTM D-1525)Maximum elongation at break > 800% (ISO 527-2)Bending radius 5 x DiametreOxygen DensityEVOH Layer (DIN 4726)MAGNUM Tube underflo..
MAGNUM Tube PE-RT 16 x 2 / 600 m
Density0,933 g/cm3 (ASTM D-792)Linear expansion coefficient, 20⁰C - 70⁰C0,19 mm/mK (DIN 53752 A)Thermal conductivity at 60⁰C0,4 Watt/mK (DIN 52612-1)Softening Point (Vicat) 122⁰C (ASTM D-1525)Maximum elongation at break > 800% (ISO 527-2)Bending radius 5 x DiametreOxygen DensityEVOH Layer (DIN 4726)MAGNUM Tube underflo..